| Working Conditions | a) Temperature range: 10°C ~ 40°C; b) Relative humidity range: 30% ~ 75%; c) Atmospheric pressure range: 700 HPA ~ 1060 HPA; d) Power supply: AC 220V±22V, frequency: 50Hz±1Hz. |
| Input Power | 250VA |
| Electromagnetic Magnetic Field Intensity |
probe A: 5~16mT probe B: 14~28mT probe C: 10~36mT probe D: 7~25mT |
| Safety Range of Magnetic Field Intensity | Magnetic field strength ≤0.5mT outside 20cm from the magnet in the environment |
| Temperature of Probes | 1st gear: 39°C; 2nd gear:42°C; 3rd gear: 45°C; 4th gear: 48°C. |
| Vibration Excitation Signal | The amplitude of vibration signal is 12V square wave, the frequency is 10kHz, and the duty ratio of square wave is different with different gear. |
Function
It main improving Liver metabolism of sugar, fat, protein and the function of microcirculation, enhance the liver storage and release function, to achieve stable blood glucose treatment effection.
Who is Suitable to Use Our Machine?
It is suitable for adjuvant treatment of type ll diabetes and related metabolic diseases.
Type 2 Diabetic Patients (Blood Glucose Control)
Suitable for patients with type 2 diabetes. It helps repair islet β-cells, improves insulin secretion and utilization when used with hypoglycemic drugs, enhances liver metabolism of sugar, fat and protein as well as microcirculation, and boosts liver storage and release functions to stabilize blood glucose and achieve an auxiliary hypoglycemic effect.
Diabetic Eye Complications
Suitable for people with diabetic fundus lesions and retinopathy. It promotes fundus blood circulation, helps remove toxins and waste from the eyes, improves diabetic retinopathy, relieves eye discomfort, and protects eye health in diabetic patients.
Diabetic Nephropathy
Suitable for patients with diabetic nephropathy. It increases cell permeability and metabolic capacity, boosts blood circulation in the kidneys, effectively improves and protects renal function, and reduces metabolic burden on the kidneys for diabetic patients.
Diabetic Neuropathy
Suitable for people with diabetic peripheral neuropathy and other nerve injuries. It accelerates blood flow and cell metabolism, provides sufficient nutrient supply to nerve tissues, helps repair damaged nerve tissues, and relieves discomforts caused by neuropathy.
Diabetic Cardiovascular and Cerebrovascular Diseases
Suitable for diabetic patients with cardiovascular and cerebrovascular problems. It dilates blood vessels, improves systemic blood circulation, repairs vascular endothelial tissue, alleviates cardiovascular and cerebrovascular lesions caused by diabetes, and maintains cardiovascular and cerebrovascular health.
Diabetic Foot
Suitable for patients with diabetic foot. It promotes blood circulation and cell metabolism in the affected foot area, reduces inflammation and swelling, resists infection, and accelerates soft tissue repair to relieve local symptoms and support recovery of foot wounds and tissues.
Product Structure
How to Use
1.Plug the output line of the probe into the corresponding output channel port, then connect the power plug to the power socket, turn on the power switch behind the host, and turn on the power.
2.Place the probe at the correct acupuncture point of the human body and fix it with a strap. Press the “Switch” key to enter the standby state.
3.Choose the treatment prescription
- Time: the default time is 30 minutes, and the required treatment time can also be adjusted according to the needs. Press the “Time+” and “Time-” keys, and the adjustment range is 0 ~ 99 minutes, and the step is 5 minutes.
- Temperature: Default gear 1, press “Temperature+” and “Temperature-” keys to adjust the operating temperature. Temperature adjustment range 1~4.
- Strength: the default strength is 0. Press the “Strength+” and “Strength-” keys to adjust the operation strength. Intensity adjustment range 0~9.
4.When adjusting the intensity, it should be adjusted slowly from the minimum, limited by human tolerance, and the intensity should not be increased too quickly or excessively to prevent accidents. When the human body has adapted to the current intensity, the intensity can be appropriately increased.
5.After the time and intensity are set, press the “Start/Stop” button to start the treatment.
6.Press the “Start/Stop” key at any time to stop the operation, and the instrument will enter the standby state, and the time will return to the default value.
7.After the running time is over, the machine stops working, and there is a buzzer alarm prompt. Press the “Switch” key to turn off the host power.
8.Usage time and frequency:1-2 times a day, each time for 30-40 minutes.
Guidance of Acupoint Selection
(1)Probe “wood” placement: Mingmen point and Shenshu point
(2)Probe “fire” placement: the left portal point
(3)Probe “earth” placement: Shenque point, Qihai point and Guanyuan point
(4)Probe “gold” and “water” placement: put it at the left and right Zusanli points or Sanyinjiao points in the morning and Yongquan points in the afternoon.
Product Principle
Packing Lists
| Name | Quantity |
| Host | 1 |
| Power cord | 1 |
| Therapeutic probe (with output line) | 5 |
| Operation Instruction | 1 |
| Backup Fuse | 2 |